SCANNER OPERATION
Failure Mode Indicators
Flashing Blue and One Razzberry Tone
This indicates that the scanner has experienced a laser subsystem failure.
Return the unit to an authorized service center for repair.
Flashing Blue and White and Two Razzberry Tones
This indicates that the scanner has experienced a motor failure. Return the unit
to an authorized service center for repair.
Continuous Razzberry Tone with Both LEDs Off
If, upon power up, the scanner emits a continuous razzberry tone, then the
scanner has an electronic failure. Return the unit to an authorized service
center for repair.
Three Beeps - On Power Up
If the scanner beeps 3 times on power up, then the nonvolatile memory that
holds the scanner configuration has failed. Return the unit to an authorized
service center for repair.